Journal of Clinical Densitometry
Volume 13, Issue 1 , Pages 29-35 , January 2010

Some Physical and Clinical Factors Influencing the Measurement of Precision Error, Least Significant Change, and Bone Mineral Density in Dual-Energy X-Ray Absorptiometry

  • Jeffrey Frimeth

      Affiliations

    • Department of Physics, Laurentian University, Sudbury, Ontario, Canada
  • ,
  • Eduardo Galiano

      Affiliations

    • Department of Physics, Laurentian University, Sudbury, Ontario, Canada
    • Corresponding Author InformationAddress correspondence to: Eduardo Galiano, PhD, Department of Physics, Laurentian University, Ramsey Lake Road, Sudbury, ON P3E 2C6, Canada.
  • ,
  • Dave Webster

      Affiliations

    • Department of Nuclear Medicine, Sudbury Regional Hospital, St. Joseph's Site, Sudbury, Ontario, Canada

Received 30 July 2009 ,Revised 15 September 2009 ,Accepted 16 September 2009.

References 

  1. Andreo P, Evans MDC, Hendry JH, et al. Radiation oncology physics: a handbook for teachers and students. 1st ed. Vienna: International Atomic Energy Agency; 2005;
  2. Baim S, Binkley N, Bilezikian JR, et al. Official positions of the International Society for Clinical Densitometry and executive summary of the 2007 ISCD Position Development Conference. J Clin Densitom. 2008;11:75–91
  3. Kolta S, Ravaud P, Fechtenbaum J, et al. Accuracy and precision of 62 bone densitometers using a European Spine Phantom. Osteoporos Int. 1999;10:14–19
  4. Khan AA, Brown J, Faulkner K, et al. Standards and guidelines for performing central dual X-ray densitometry from the Canadian panel of international society for clinical densitometry. J Clin Densitom. 2002;5:435–445
  5. Bonnick SL. Bone densitometry in clinical practice: application and interpretation. 2nd ed. New Jersey: Humana Press Inc; 2004;
  6. Baim S, Wilson CR, Lewiecki EM, et al. Precision assessment and radiation safety for dual-energy X-ray absorptiometry. J Clin Densitom. 2005;8:371–378
  7. Leslie W. The importance of spectrum bias on bone density monitoring in clinical practice. Bone. 2006;39:361–368
  8. Leslie WD, Ward LM for the Manitoba Bone Density Program. Bone density monitoring with the total hip site. J Clin Densitom. 2004;7:269–274
  9. Morgan SL, Abercrombie W, Lee JY. Need for precision studies at individual institutions and assessment of size of regions of interest on serial DXA scans. J Clin Densitom. 2003;6:97–101
  10. Nielsen SP, Barenholdt O, Diessel E, et al. Linearity and accuracy errors in bone densitometry. Br J Radiol. 1998;71:1062–1068
  11. Kiebzak GM, Faulkner KM, Wacker W, et al. Effect of percision error on T-scores and the diagnostic classification of bone status. J Clin Densitom. 2007;10:239–243
  12. Larkin A, Sheahan N, O'Connor U, et al. QA/acceptance testing of DEXA X-ray systems used in bone mineral densitometry. Rad Prot Dosim. 2008;129:279–283

PII: S1094-6950(09)00233-9

doi: 10.1016/j.jocd.2009.09.004

Journal of Clinical Densitometry
Volume 13, Issue 1 , Pages 29-35 , January 2010