In Vivo and In Vitro Comparison of Densitometers in the NOREPOS Study
References
- . Technical principles of dual energy x-ray absorptiometry. Semin Nucl Med. 1997;27:210–228
- . Accuracy and precision of 62 bone densitometers using a European Spine Phantom. Osteoporos Int. 1999;10:14–19
- . A comparison of phantoms for cross-calibration of lumbar spine DXA. Osteoporos Int. 2002;13:948–954
- Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration results. J Bone Miner Res. 1994;9:1503–1514
- European semi-anthropomorphic spine phantom for the calibration of bone densitometers: assessment of precision, stability and accuracy. The European Quantitation of Osteoporosis Study Group. Osteoporos Int. 1995;5:174–184
- . The European Spine Phantom—a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT. Eur J Radiol. 1995;20:83–92
- . Cross-calibration of GE/Lunar pencil and fan-beam dual energy densitometers—bone mineral density and body composition studies. Eur J Clin Nutr. 2003;57:977–987
- . Cross-calibration, precision and patient dose measurements in preparation for clinical trials using dual energy X-ray absorptiometry of the lumbar spine. Br J Radiol. 1999;72:354–362
- . Dual X-ray absorptiometry: cross-calibration of a new fan-beam system. Calcif Tissue Int. 2004;75:7–14
- . Replacing DXA scanners: cross-calibration with phantoms may be misleading. Calcif Tissue Int. 1996;59:1–5
- . Standardization of postero-anterior (PA) spine BMD measurements by DXA. Committee for Standards in DXA. Bone. 1995;17:435
- . Cross calibration of DXA as part of an equipment replacement program. J Clin Densitom. 2006;9:287–294
- . Axial and total-body bone densitometry using a narrow-angle fan-beam. Osteoporos Int. 2000;11:158–166
- . Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int. 1995;5:262–270
- . Measurement error. BMJ. 1996;313:744
- . Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135–160
- . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–310
- . Applied longitudinal analysis. New Jersey: John Wiley & Sons; 2004;
- Cross-calibration of Lunar DPX-IQ and DPX dual-energy x-ray densitometers for bone mineral measurements in women: effect of body anthropometry. J Clin Densitom. 2005;8:320–329
- . Evaluation of differences between fan-beam and pencil-beam densitometers. Calcif Tissue Int. 2000;67:291–296
- . Pediatric in vivo cross-calibration between the GE Lunar Prodigy and DPX-L bone densitometers. Osteoporos Int. 2005;16:2157–2167
The NOREPOS Research Group: The Core Research Group (in alphabetic order): Nina Emaus (Tromsø), Haakon E. Meyer (Oslo), Berit Schei (Nord-Trøndelag), and Grethe S. Tell (Bergen). Local collaborators (in alphabetic order): Bergen: Gjesdal CG, Tell GS; Nord-Trøndelag: Forsén L, Forsmo S, Langhammer A, Schei B; Oslo: Falch JA, Meyer HE, Søgaard AJ; Tromsø: Berntsen GKR, Emaus N, Fønnebø V, Joachimsen RM.
PII: S1094-6950(07)00211-9
doi: 10.1016/j.jocd.2007.10.001
© 2008 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Clinical Densitometry
Volume 11, Issue 2
, Pages 276-282
, April 2008