Journal of Clinical Densitometry
Volume 10, Issue 3 , Pages 306-311 , July 2007

Cross Calibration of Hologic QDR2000 and GE Lunar Prodigy for Forearm Bone Mineral Density Measurements

  • D. Pearson

      Affiliations

    • Department of Medical Physics & Clinical Engineering, Nottingham University Hospitals NHS Trust, Nottingham, UK
    • Corresponding Author InformationAddress correspondence to: Derek Pearson, Medical Physics & Clinical Engineering, Nottingham University Hospitals NHS Trust, City Hospital Campus, Hucknall Road, Nottingham, NG5 1PB, United Kingdom.
  • ,
  • B. Horton

      Affiliations

    • Department of Radiology, Nottingham University Hospitals NHS Trust, Nottingham, UK
  • ,
  • D.J. Green

      Affiliations

    • Department of Radiology, Nottingham University Hospitals NHS Trust, Nottingham, UK

Received 1 February 2006 ,Revised 26 April 2007 ,Accepted 14 May 2007.

References 

  1. Hamdy RC, Petak SM, Lenchik L International Society for Clinical Densitometry Position Development Panel and Scientific Advisory Committee. Which central dual X-ray absorptiometry skeletal sites and regions of interest should be used to determine the diagnosis of osteoporosis?. J Clin Densitom. 2002;5(Suppl):S11–S18
  2. Adami S, Braga V, Squaranti R, Rossini M, Gatti D, Zamberlan N. Bone measurements in asymptomatic primary hyperparathyroidism. Bone. 1998;22:565–570
  3. Writing Group for the ISCD Position Development Conference. Diagnosis of osteoporosis in men, premenopausal women, and children. J Clin Densitom. 2004;7:17–26
  4. Matkovic V, Goel PK, Badenhop-Stevens NE, et al. Calcium supplementation and bone mineral density in females from childhood to young adulthood: a randomized controlled trial. Am J Clin Nutr. 2005;81:175–188
  5. Ducher G, Prouteau S, Courteix D, Benhamou CL. Cortical and trabecular bone at the forearm show different adaptation patterns in response to tennis playing. J Clin Densitom. 2004;7:399–405
  6. McClung MR, Wasnich RD, Hosking DJ, et al. Prevention of postmenopausal bone loss: six-year results from the Early Postmenopausal Intervention Cohort Study. J Clin Endocrinol Metab. 2004;89:4879–4885
  7. Gutteridge DH, Retallack RW, Ward LC, et al. Bone density changes in Paget's disease 2 years after iv pamidronate: profound, sustained increases in pagetic bone with severity-related loss in forearm nonpagetic cortical bone. Bone. 2003;32:56–61
  8. Hagiwara S, Engelke K, Yang SO, et al. Dual x-ray absorptiometry forearm software: accuracy and intermachine relationship. J Bone Miner Res. 1994;9(9):1425–1427
  9. Abrahamsen B, Gram J, Hansen TB, Beck-Nielsen H. Cross calibration of QDR-2000 and QDR-1000 dual-energy X-ray densitometers for bone mineral and soft-tissue measurements. Bone. 1995;16(3):385–390
  10. Bouyoucef SE, Cullum ID, Ell PJ. Cross-calibration of a fan-beam X-ray densitometer with a pencil-beam system. Br J Radiol. 1996;69(822):522–531
  11. Soriano JM, Ioannidou E, Wang J, et al. Pencil-beam vs fan-beam dual-energy X-ray absorptiometry comparisons across four systems: body composition and bone mineral. J Clin Densitom. 2004;7(3):281–289
  12. Kiebzak GM, Lewiecki EM, Petak SM. Impact of using the ultradistal radius region of interest on diagnostic classification. J Clin Densitom. 2004;7:143–152
  13. Pearson D, Cawte SA, Green DJ. A comparison of phantoms for cross-calibration of lumbar spine DXA. Osteoporos Int. 2002;13(12):948–954
  14. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–310
  15. Feldmann U, Schneider B, Klinkers H, Haeckel R. A multivariate approach for the biometric comparison of analytical methods in clinical chemistry. J Clin Chem Clin Biochem. 1981;19(3):121–137
  16. Pearson D, Horton B, Green DJ. Cross calibration of DXA as part of an equipment replacement program. J Clin Densitom. 2006;9:287–294
  17. Griffiths MR, Noakes KA, Pocock NA. Correcting the magnification error of fan beam densitometers. J Bone Miner Res. 1997;12:119–123
  18. Pearson J, Ruegsegger P, Dequeker J, et al. European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability. Bone Miner. 1994;27:109–120
  19. Ruegsegger P, Kalender WA. A phantom for standardization and quality control in peripheral bone measurements by PQCT and DXA. Phys Med Biol. 1993;38:1963–1970
  20. Emaus N, Berntsen GK, Joakimsen R, Fonnebo V. Bone mineral density measures in longitudinal studies: the choice of phantom is crucial for quality assessment. The Tromso study, a population-based study. Osteoporos Int. 2005;16:1597–1603
  21. Kolta S, Ravaud P, Fechtenbaum J, Dougados M, Roux C. Accuracy and precision of 62 bone densitometers using a European Spine Phantom. Osteoporos Int. 1999;10:14–19

PII: S1094-6950(07)00174-6

doi: 10.1016/j.jocd.2007.05.003

Journal of Clinical Densitometry
Volume 10, Issue 3 , Pages 306-311 , July 2007