Journal of Clinical Densitometry
Volume 9, Issue 3 , Pages 315-322, July 2006

Simulated Change in Body Fatness Affects Hologic QDR 4500A Whole Body and Central DXA Bone Measures

  • Ellen M. Evans

      Affiliations

    • Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL
    • Division of Nutritional Sciences, University of Illinois at Urbana-Champaign, Urbana, IL
    • Corresponding Author InformationAddress correspondence to: Ellen M. Evans, 215 Freer Hall, MC-052, 906 S. Goodwin Ave., Department of Kinesiology & Community Health, University of Illinois, Urbana, IL 61801.
  • ,
  • Mina C. Mojtahedi

      Affiliations

    • Division of Nutritional Sciences, University of Illinois at Urbana-Champaign, Urbana, IL
  • ,
  • Renee B. Kessinger

      Affiliations

    • Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL
  • ,
  • Mark M. Misic

      Affiliations

    • Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL

Received 27 January 2006; accepted 21 April 2006.

Abstract 

Changes in body fatness may impact the accuracy of dual energy X-ray absorptiometry (DXA) measures of bone mineral content (BMC) and bone mineral density (BMD). The aim of this study was to determine if DXA can accurately assess BMC and BMD with changes in exogenous fat (lard) placed to simulate weight change. Whole body (WB), lumbar spine (LS), and proximal femur (PF) DXA scans (Hologic QDR 4500A) were performed on 30 elderly (52–83 yr) and 60 young (18–40 yr) individuals (i.e., 45 females and 45 males) of varying body mass index (mean±standard deviation: 26.1±4.9 kg/m2). When scans were repeated with lard packets (2.54 cm thick, 25.4×17.8 cm, 1 kg), WB BMD decreased 1.1% and 1.6% after chest and thigh packet placement, respectively (p=0.001), PF BMD increased 0.7% (p=0.02) and LS BMD decreased 1.6% (p=0.001) primarily due to a 2.2% reduction in LS BMC (p<0.001). Initial LS BMC and trunk mass were related to error in LS BMC measures due to lard-loading (r=0.64 and 0.45, respectively, p<0.001). We conclude that on average simulated weight change minimally impacts PF bone measures and moderately impacts WB and LS bone measures; however, individual variability in measurement error was noteworthy and may be impacted by body thickness.

Key Words: Central measures, technique, whole body

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1094-6950(06)00191-0

doi:10.1016/j.jocd.2006.04.117

Journal of Clinical Densitometry
Volume 9, Issue 3 , Pages 315-322, July 2006