Journal of Clinical Densitometry
Volume 9, Issue 3 , Pages 281-286, July 2006

Monitoring of Dual-Energy X-ray Absorptiometry Measurement in Clinical Practice

Rheumatology and Physical Rehabilitation Department, Military Hospital Mohammed V, Rabat, Morocco

Received 30 November 2005; received in revised form 18 March 2006; accepted 18 March 2006.

Abstract 

Bone densitometry has become the “gold standard” in osteoporosis diagnosis and treatment evaluation. It has also become more and more common to perform a second dual-energy X-ray absorptiometry (DXA) measurement to monitor bone mineral density (BMD) status or the effect of therapeutic intervention. When a second measurement is performed on a patient, the clinician needs to distinguish between a true change in BMD and a random fluctuation related to variability in the measurement procedure. The reproducibility of DXA measurements is claimed to be good. Such variability is due to multiple causes, such as device errors, technician variability, patients' movements, and variation due to other unpredictable sources. The precision error is usually expressed as the coefficient of variation (CV). However, several other statistics to express reproducibility exist such as the smallest detectable difference (SDD) or the least significant change (LSC). The SDD represents a cut-off that can be measured in an individual and is usually considered more useful than the CV in clinical practice. Indeed, the use of the SDD is preferable to the use of the CV and LSC because of its independence from BMD level and its expression in absolute units (g/cm2). At each measurement center, the SDD must be calculated from in vivo reproducibility data. The choice of the optimum time and site for performing follow-up scans depends on the ratio of the expected BMD treatment effect to the precision of the measurements.

Key Words: Bone mineral density, dual-energy X-ray absorptiometry, reproducibility

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1094-6950(06)00043-6

doi:10.1016/j.jocd.2006.03.014

Journal of Clinical Densitometry
Volume 9, Issue 3 , Pages 281-286, July 2006