Journal of Clinical Densitometry
Volume 9, Issue 2 , Pages 159-163 , April 2006

Calcium Supplement Ingestion May Alter Lumbar Spine Bone Mineral Density Measurement

Received 12 October 2005 ,Revised 26 December 2005 ,Accepted 16 January 2006.

References 

  1. Watts NB. Fundamentals and pitfalls of bone densitometry using dual-energy x-ray absorptiometry (DXA). Osteoporos Int. 2004;15:847–854
  2. Jacobson JA, Jamadar DA, Hayes CW. Dual x-ray absorptiometry: recognizing image artifacts and pathology. Am J Roentgenol. 2000;174:1699–1705
  3. Liu G, Peacock M, Eilam O, Dorulla G, Braunstein E, Johnston CC. Effect of osteoarthritis in the lumbar spine and hip on bone mineral density and diagnosis of osteoporosis in elderly men and women. Osteoporos Int. 1997;7:564–569
  4. Frye MA, Melton LJ, Bryant SC, et al. Osteoporosis and calcification of the aorta. Bone Miner. 1992;19:185–194
  5. Drinka PJ, DeSmet AA, Bauwens SF, Rogot A. The effect of overlying calcification on lumbar bone densitometry. Calcif Tissue Int. 1992;50:507–510
  6. Orwoll ES, Oviatt SK, Mann T. The impact of osteophytic and vascular calcifications on vertebral mineral density measurements in men. J Clin Endocrinol Metab. 1990;70:1202–1207
  7. Hauache OM, Vieira JGH, Alonso G, Martins LRF, Brandao C. Increased hip bone mineral density in a woman with gluteal silicon implant. J Clin Densitom. 2000;3:391–393
  8. Rivera M, Humeres P, Gonzalez P. Increased bone mineral density in dual x-ray densitometry due to gluteal implants. J Clin Densitom. 1998;24(1):51–53
  9. Bonnick SL, Lewis LA. Bone densitometry for technologists. New Jersey: Humana Press; 2002;84–88
  10. Bohdiewicz PJ, Kahn A. A dual-energy x-ray absorptiometry artifact and potential pitfall the nonremovable umbilical ring. Clin Nucl Med. 2002;27(12):911–912
  11. Binkley N, Krueger D, Vallarta-Ast N. An overlying fat panniculus affects femur bone mass measurement. J Clin Densitom. 2003;6:199–204
  12. Kirac FS, Yuksel D, Yaylali OT. Pitfalls in the measurement of bone mineral density by the dual-energy x-ray absorptiometric method. Clin Nucl Med. 2001;26:874–875
  13. Chan PS, Binkley NC, Lalande BM, Young S, Shaker JL. Artifactual reduction in bone density as a result of Technetium-99m MDP for bone scanning. J Clin Densitom. 2004;7:457–458
  14. RadiologyInfo Bone Densitometry. 2005 (10/6/05, http://www.radiologyinfo.com/content/dexa.htm).
  15. Srikureja DP, Speith M, Suarino V. Density of 100+ pills compared to a phantom transverse process. J Clin Densitom. 2004;7:230
  16. Precision assessment and radiation safety white paper. 2005 (10/8/05, http://www.iscd.org/visitors/resources/index.cfm).
  17. Robertson S, Kendler D. Calcium tablet artifact effects on spine DXA. J Clin Densitom. 2004;7:223
  18. Kiebzak G, Schmeer P, Van Pelt J. Insoluble intestinal calcium complexes may affect monitoring but not diagnosis. J Clin Densitom. 2004;7:239

PII: S1094-6950(06)00021-7

doi: 10.1016/j.jocd.2006.01.002

Journal of Clinical Densitometry
Volume 9, Issue 2 , Pages 159-163 , April 2006